Buy AND UA-888AC E auto tonometer with adapter

AND UA-888AC E auto tonometer with adapter

Condition: New product

1000 Items

89,31 $

More info

Description

Automatic tonometer A & D UA-888AC is designed to measure the values ​​of systolic (upper), diastolic (lower) pressure and heart rate (pulse). The device is based on an oscillometric measurement method. Device: has a universal cuff of the new generation Opti Cuff 23-37 cm, allows you to measure pressure to consumers with medium and full hands, has an arrhythmia indicator, a memory for 30 measurements, the calculation of the average pressure. For ease of use, the texts on the instrument and cuff are written in Russian. Included is a case for storage.

Composition

Main unit in the case, standard cuff, connecting tube, connector, storage pouch, batteries (AA, R6) - 4 pcs.

Indications

For measuring systolic (upper), diastolic (lower) pressure and heart rate (pulse) values.

Precautionary measures

Do not allow the unit to fall or hit hard, as this may cause damage. Do not use the device near a TV, microwave oven, cell phone, X-ray emitter or other device with a strong electromagnetic field.

Use during pregnancy and lactation

Not contraindicated in pregnancy and lactation.

Dosage and administration

Plug the adapter plug into the network connector on the back of the instrument. Turn on the AC power adapter. Firmly insert the connector of the connecting tube into the connector located on the side panel of the device. Place a cuff on the shoulder at a distance of 1-2 cm from the elbow. Do not roll up the sleeves of clothes (this can interfere with the flow of blood in the vessels) and do not measure in clothes made of thick fabric. A measurement with a loosely sealed cuff may give unreliable results. It is not allowed to pump the cuff loose or loosely attached to the shoulder, as this may lead to its rupture. Press the START button. All characters appear on the display for a few seconds. Then, the display will show the symbol 0, and the device will automatically pump up the cuff to the amount of pressure required for the measurement. In the process of inflation, the amount of air pressure in the cuff is displayed on the display both in the form of numbers on the right side of the display and graphically on the six-segment display.The maximum pressure value corresponds to the flashing of all six segments of the graphic indicator. Attention: if necessary, you can interrupt the measurement by pressing the START button. After the pressure in the cuff reaches the value required for the measurement, the automatic release of air from the cuff will begin, and the symbol will flash - the measurement is in progress. The symbol appears when a pulse is detected. Do not talk or move during the measurement. After the measurement is completed, the remaining air in the cuff is automatically released, and the display shows the blood pressure values ​​(systolic SYS (upper), diastolic DIA (lower)) and pulse simultaneously. Remove the cuff and turn off the device by briefly pressing the START button. If no operation was performed within a minute, the device will turn off automatically. If a series of measurements is carried out, the interval between them must be at least three minutes.

special instructions

How to measure pressure correctly. For the most accurate results, take a rest for 5–10 minutes before measuring. Sit comfortably and place your hand in front of you on the table, palm up. Position your arm so that the cuff is at heart level. Do not move or speak during the measurement. Do not measure immediately after taking a bath, playing sports or other physical exercises. Rest for 20-30 minutes. Try to measure pressure at the same time every day. Always follow the doctor's recommendations.

Reviews